DMM AMM
Vs = 12.00
Vs = 9.0
 
Rm = 10,000 kW = 10 MW
 
Rm = 200 kW
  With Meter Loading   With Meter Loading
Calculated Measured Calculated Measured
 
kW
V
NO
Load
Req
kW

V'

% diff

V'

% diff
from
no load
% diff
from
loaded
V
NO
Load
Req
kW
V' % diff V' % diff
from
no load
% diff
from
loaded

Branch A

R1  1.230 3.746 1.230 3.746 -0.008 3.75 0.102 0.110 2.810 1.222 2.798 -0.421 2.8 -0.343 0.078
R2  2.71 8.254 2.709 8.253 -0.008 8.25 -0.046 -0.038 6.190 2.674 6.164 -0.421 6.2 0.156 0.579
Branch B
R1  26.7 3.893 26.629 3.886 -0.180 3.89 -0.079 0.101 2.920 23.56 2.678 -8.273 2.7 -7.528 0.812
R2  55.6 8.107 55.293 8.092 -0.180 8.09 -0.209 -0.029 6.080 43.51 5.577 -8.273 5.6 -7.898 0.409
Branch C
R1  556 3.810 526.7 3.671 -3.656 3.67 -3.685 -0.030 2.858 147.1 0.986 -65.485 1.0 -65.008 1.381
R2  1195 8.190 1067.4 7.890 -3.656 7.89 -3.658 -0.003 6.142 171.3 2.120 -65.485 2.1 -65.810 -0.944
  MLE   Total
Error
This
includes
all
errors
other
than the
meter
loading
error
  MLE   Total
Error
This
includes
all
errors
other
than the
meter
loading
error